Model MATS-2010H |
 |
|
|
|
Automatic measurement of the demagnetization curve of permanent magnetic material such as ferrite, AlNiCo, NdFeB, SmCo, etc. Accurate measurement of the magnetic characteristic parameters of remanence Br, coercive force HcB, intrinsic coercive force HcJ and maximum magnetic energy product (BH)max.
Windows measurement software applied simply. The product conforms to China National Standards GB/T 3217-92, GB 11209-89 and international standard IEC 404-5.
Adopt ATS structure, users can customize different configuration as required: According to the intrinsic and size of measured sample to decide the electromagnetic size and corresponding testing power supply; Select different measuring coil and probe according to the option of measuring method. Decide to whether choosing fixture in accordance with sample shape. Decide to whether selecting heating installation or not according to the test requirement. |
|
System Specifications
Test AlNiCo standard sample, measuring error on entire magnetic hysteresis cycle estimated: B: 1%, H: 1%
Parameters measured |
Br (%) |
HcB (%) |
HcJ (%) |
(BH)max (%) |
Uncertainty (k = 2) |
1 |
1 |
1 |
2 |
Repeatability (constant temperature) |
± 0.3 |
± 0.3 |
± 0.3 |
± 1 |
Instrument Specifications
TPS-2000H Test Power Supply |
|
DCT130 Electromagnet |
Output Voltage: 0 ~ ±100 V Output Current: ±20 A (maximum value) Stability: superior to 0.05% Output protection: overvoltage, overflowing, short-circuits protection |
Head Diameter: 130 mm Head Spacing: 0 ~ 50 mm (continual adjustable) Maximal Magnetic Field: 1.5 T (head spacing 10 mm, coil current 20 A) |
TPS-2100H Test Power Supply |
DCT150 Electromagnet |
Supply Voltage: single phase, 220V 50Hz Output Voltage: 0 ~ ±120 V Output Current: ±30 A (maximum value) Output protection: overvoltage, overflowing, short-circuits protection |
Head Diameter: 150 mm shrink to 80 mm Head Spacing: 0 ~ 50 mm (continual adjustable) Maximal Magnetic Field: 2.4 T (head spacing 10 mm,coil current 30 A) |
TPS-2200H Test Power Supply |
DCT200 Electromagnet |
Supply Voltage: single phase, 220V 50Hz Output Voltage: 0 ~ ±200 V Output Current: ±60 A (maximum value) Output protection: overvoltage, overflowing, short-circuits protection |
Head Diameter: 200 mm shrink to 80 mm Head Spacing: 0 ~ 50 mm (continual adjustable) Maximal Magnetic Field: 2.7 T (head spacing 10 mm, coil current 60 A) |
TPS-2300H Test Power Supply |
DCT250 Electromagnet |
Supply Voltage: three phase, 380V 50Hz Output Voltage: 0 ~ ±300 V Output Current: ±60 A (maximum value) Output protection: overvoltage, overflowing, short-circuits protection |
Head Diameter: 250 mm shrink to 80 mm Head Spacing: 0 ~ 80 mm (continual adjustable) Maximal Magnetic Field: 2.8 T (head spacing 10 mm, coil current 60 A) |
LZ-210B Fluxmeter |
|
PC6023 A/D D/A card |
Range: 2.5, 5, 10, 20 mWb Full Range Precision: 0.5% Zero Shift: 2 μWb / 30 seconds (2.5 mWb) |
A/D Conversion: 12 bits, 4 channels Conversion Time: < 10 μs Conversion Accuracy: 0.1% (full range) D/A Conversion: 12 bits, 2 channels Conversion Accuracy: 0.1% (full range) |
LZ-210H Magnetometer |
PC6016 A/D D/A card
|
Range: 0.5, 1, 1.5, 3 T Full Range Precision: 0.5% Non-Linearity: ±0.2% (software correction) |
A/D Conversion: 16 bits, 8 channels differential input Conversion Time: < 10 μs Conversion Accuracy: 0.01% (full range) D/A Conversion: 16 bits, 2 channels Conversion Accuracy: 0.01% (full range) | |
Correlative Services |
|
|
|