    Model MATS-2010SD

     
  Model MATS-2010SD Hysteresisgraph  
     
Automatic measurement on basic magnetization curve and magnetic hysteresis loop under static state of soft magnetic material, accurate measurement on static magnetic characteristic parameters such as initial permeability μi, maximum permeability μm, saturation magnetic induction Bs, remanence Br, coercive Hc and hysteresis losses Pu.

Windows measurement software applied simply. It conforms to China National Standards GB 3656-83, GB 3657-83, GB/T 13012-91, GJB 937-90, industry standard SJ/T 10281-91 and international standard IEC 60404-4, IEC 404-7.

In accordance with measuring principle of ballistic method, combine computer control technology, A/D and D/A, replace conventional ballistic galvanometer with electronic integrator, realize analog ballistic method measurement under microcomputer control, can completely eliminate non-instant error caused by ballistic galvanometer in classical ballistic method, with high measurement accuracy, fast speed and good repeatability, can eliminate the influence of various artificial factors, and supply reliable basis for research on material magnetization process.

      General Features       Software Features       Software Screen       Technical Data       Standard Package  

System Specifications

Adopt ballistic method measurement, technical indices as follows:

Parameters measured Bs (%) Br (%) Hc (%) Pu (%) μ m (%) μ i (%)
Uncertainty (k = 2) 1 1 1.5 1 2 5
Repeatability (constant temperature) ± 0.5 ± 0.5 ± 0.5 ± 0.5 ± 1 ± 3

When testing hysteresis loop with scanning method, H and B measuring errors can be estimated as:
B: 1% + 1/2 LSB
H: 1% + 1/2 LSB

Instrument Specifications

MATS - 2010SD Static Hysteresisgraph   PC6016 A/D D/A Card
    Output Voltage: 0 ~ ±35 V
    Output Current: 0.01 mA ~ 10 A
    Current Range: 1 mA, 2 mA, 5 mA, 10 mA, 20 mA, 50 mA, 100 mA, 200 mA,
                                 500 mA, 1 A, 2 A, 5 A, 10 A total 13 automatic ranges
    Stability: superior to 0.05%
    Flux Range: 0.25, 0.5, 1, 2, 5, 10, 20 mWb, total seven automatic ranges
    Sensitivity: 0.05 μWb (ballistic method)
                        0.1 μWb (magnetic field sweep)
    A / D Conversion: 16 bits, 8 channels differential input
    Conversion Time: < 10 μs
    Conversion Accuracy: 0.01% (full range)
    D/A Conversion: 16 bits, 2 channels
    Conversion Accuracy: 0.01% (full range)
    Bus Structure: PCI busbar